XTS03-5 Scan gate form: Full case through the gate · three readers
Three industrial readers mounted on the gate frame: a full case or pallet is verified in one pass - no unboxing and item-by-item scanning. Built for batch checkpoints at inbound/outbound doors and case-verification positions.
Configuration & specifications
From the current datasheets; the shipping datasheet governs.
| Item | Content |
|---|---|
| Model | XTS03-5 |
| Form | Scan gate (batch through-gate verification) |
| Standard package | Scan-to-verify software ×1; XT802F-X86 industrial PC ×1; gate bracket ×1; junction box ×1; XT8601B industrial readers ×3; XT8161 ×1 |
| Options | Industrial reader XT9202B; multi-reader field-of-view stitching; line-stop controller, reject controller |
| Customization | Build-to-order supported |
| Warranty | 12 months (per the warranty service agreement), 5×8-hour technical support |
Key functions
Pre-loaded comparison
Load the barcodes that should pass into the database first. During production, each scanned code is compared with the pre-loaded list: match = pass, mismatch = NG.
OK / NG dual-channel alerts
An external horn plus the industrial PC report OK with a green light; codes not on the list or duplicate scans trigger an NG warning tone, a red light, and an NG signal output.
NG signal linked to the line
The NG signal output can be wired to line-stop or reject mechanisms so defective items do not move downstream.
Three scan modes
Single-product scanning, batch out-of-order scanning, and batch full-pallet scanning, switched to match the workstation rhythm.
Data logging
Scan records can be exported to spreadsheets; full-case scanning supports automatic binding of product codes to case codes.
Where it fits - and where it doesn't
Choose it for these
- Case verification: product codes bound to the case code
- Full cases and pallets passing through inbound/outbound gates
- Checkpoints where unboxing item-by-item is impractical
Consider another for these
- Fine single-item, small-code comparison (desktop fits better)
- Loose-item stations without a stable through-gate route

Applications
Case verification and inbound/outbound gates in food, pharma, daily chemicals, and 3C.
FAQ
How do I set the comparison rules?
Pre-load the barcodes that are allowed to pass into the database, then compare scans against that list during production. Per the datasheet: barcode-length comparison, quantity matching, and database duplicate checks are supported (the XTS11 software adds up to 100 conditional rules; XTS03 capabilities are confirmed in a live demo).
Can it connect to our MES?
The system supports serial port, TCP Server / TCP Client, Http/Https, and MES data output (explicitly listed in the XTS11 datasheets). Default configurations for each XTS03 variant follow the datasheets; confirm the integration method with an engineer before ordering.
What happens when a scan fails?
On NG (code not on the pre-loaded list, duplicate scan, etc.) the system sounds a warning tone with a red light and outputs an NG signal; lines wired to line-stop or reject mechanisms act automatically, while others rely on the audible and visual alert for manual handling.
Related systems
They differ in scan position and batch size - open and compare.
Describe your line, and the configuration follows
Where you scan, what code, how fast the takt, where results go - state these four things and our engineers will configure the system directly.